Capacity 2000 – 3000 – 4000 - 5000 - 7500* kg
Up to 4000 divisions OIML-R60 Measuring element from steel alloy Protected against corrosion by nickel-plated treatment Available in stainless steel Protected against humidity IP-67 Avalable in ATEX version (optional) [II 1GD Ex ia IIC T4...T6 Ga] [II 1GD Ex ia IIIC T135ºC Da]
Technical data Accuracy class | C3-C4 | Rated output | 2 ± 0.1% mV/V | Vmin | Emax/10000 | Excitation Voltage | 5÷15V | Input Resistance | 350 ± 3Ω | Output Resistance | 350 ± 3Ω | Temperature Compensation | -10ºC/+40ºC | Temperature limits | -30ºC/ +70ºC | Insulation resistance | > 5000 MΩ |
|